Application Expertise

Climate Solutions Engineered for Your Industry

Every sector has unique thermal demands. Our systems are configured for the specific temperature ranges, redundancy requirements, and compliance standards of each application — with over 6,500 installations commissioned since 2003 across 45 countries.

Data center precision cooling
Critical Infrastructure

Data Centers

Precision cooling solutions maintaining +/-0.5°C temperature stability with N+1 redundancy configurations. Our water-cooled chillers with VFD compressors achieve PUE targets below 1.3, while free cooling economizers reduce annual energy consumption by 30-40% in temperate climates.

  • Capacity Range: 200 kW to 5,000 kW per module
  • Temperature Tolerance: ±0.5°C
  • Redundancy: N+1 and 2N configurations
Discuss Your Project
Pharmaceutical cleanroom HVAC
Life Sciences

Pharmaceutical & Biotech

GMP-compliant climate systems for cleanrooms, laboratories, and production environments. Our air handling units provide HEPA-grade filtration, precise humidity control (35-65% RH), and full IQ/OQ/PQ validation documentation to accelerate regulatory approval timelines.

  • Cleanroom Class: ISO 5 to ISO 8
  • Humidity Control: ±2% RH
  • Validation: IQ/OQ/PQ packages included
Request Consultation
Commercial building HVAC system
Built Environment

Commercial Buildings

Central chilled water plants, variable refrigerant flow systems, and smart building integrations designed for ASHRAE 90.1 compliance and LEED certification. Our systems serve office towers, retail complexes, hospitals, and educational institutions across 45+ countries.

  • System Types: Chilled water, VRF, split systems
  • Compliance: ASHRAE 90.1, LEED, BREEAM
  • Controls: BACnet/Modbus BMS integration
Get a Quote
Cold chain warehouse refrigeration
Supply Chain

Cold Chain & Food Processing

HACCP-compatible refrigeration systems from blast freezers operating at -40°C to chilled distribution warehouses at +2°C. Cascade refrigeration with CO2/NH3 natural refrigerant combinations achieves system COP above 3.8 while meeting FDA 21 CFR and EU Regulation 852/2004 food safety requirements.

  • Temperature Range: -40°C to +15°C
  • Refrigerants: CO2/NH3 cascade, R-290
  • Compliance: HACCP, FDA 21 CFR
Talk to an Expert
Industrial process cooling
Heavy Industry

Industrial Processing

High-capacity process chillers and heat exchangers for chemical plants, steel mills, automotive manufacturing, and plastics processing. Our shell-and-tube heat exchangers handle pressures up to 40 bar with fouling-resistant tube materials for aggressive process fluids.

  • Capacity: Up to 10,000 kW
  • Design Pressure: Up to 40 bar
  • Materials: SS316L, titanium, Hastelloy
Request Engineering Support
Hotel HVAC fan coil
Hospitality

Hotels & Resorts

Ultra-quiet fan coil units and smart room controllers delivering individual zone comfort with sound levels below 28 dB(A). Our systems integrate with property management platforms for automated guest room pre-conditioning and energy-saving unoccupied modes.

  • Noise Level: <28 dB(A)
  • Controls: Individual zone, PMS integration
  • Energy Savings: 25-35% vs conventional
Learn More

Centralized vs. Distributed: Choosing the Right Architecture

Large facilities must decide between a central chiller plant with piped distribution or multiple smaller distributed units. The optimal choice depends on your operational profile, redundancy requirements, and expansion plans.

Centralized Plant

  • Efficiency: Higher overall COP (5.5-6.2 for water-cooled centrifugal) through optimized chiller sequencing
  • Maintenance: Single machinery room simplifies service access and monitoring
  • Heat Recovery: Easier integration with waste heat recovery for domestic hot water or process heating
  • Refrigerant: Lower total charge per unit of cooling capacity

Best fit: Large campuses, data centers >2 MW, hospitals, district cooling networks

Distributed Units

  • Redundancy: Single unit failure does not halt entire facility operations
  • Installation: Lower initial piping cost; shorter refrigerant pipe runs reduce leak risk
  • Expansion: Modular capacity additions without central plant reconfiguration
  • Footprint: No dedicated machinery room required; rooftop or zone placement

Best fit: Multi-tenant retail, phased warehouse expansions, geographically spread facilities

Representative Project Profiles

Tier IV Data Center — Frankfurt, Germany

Installed a 4,800 kW water-cooled centrifugal chiller plant with N+1 redundancy and free cooling economizers in 2022. The system maintains server inlet temperatures at 24°C ±0.5°C with measured PUE of 1.28 during the first 12 months of operation. Annual energy consumption reduced by 32% versus the facility's previous air-cooled DX system.

Pharmaceutical GMP Facility — Basel, Switzerland

Delivered 12 air handling units with HEPA filtration for ISO 7 cleanrooms in 2021, paired with 1,200 kW glycol chillers maintaining process temperatures at 7°C ±0.3°C. Full IQ/OQ/PQ validation completed within the project's 18-month timeline. Humidity control holds ±2% RH across all production zones year-round.

Cold Chain Distribution — Rotterdam, Netherlands

Commissioned a 3,200 kW cascade refrigeration system using CO2/NH3 natural refrigerants for a 45,000 m² distribution warehouse in 2023. Multi-temperature zones range from -28°C frozen storage to +4°C chilled docks. The system's combined GWP-weighted refrigerant charge is 85% lower than the equivalent HFC-based installation.

Discuss Your Industry Application

Our application engineers specialize in matching system architecture, refrigerant strategy, and control platforms to your specific operational requirements.

Start a Technical Conversation